Updates for EMZER devices


PICTURE DEVICE LATEST UPDATE
(picture for EMSCOPE missing) EMSCOPE 20/11/2026 - Update version 5.0: EMSCOPE-5.emz - 0MB
Oscilloscope: rebuilt with an acquisition memory of up to 10M points and a full trigger menu (edge, burst, external, HF reject, force). Also new: automatic measurements with statistics, time and amplitude cursors, phase and delay between traces, math traces (A+B, A−B, A×B), Average, Envelope and Peak detect modes, persistence and Autoscale.

EMI measurements
- Better marker handling: peak search, next peak, delta markers against a reference marker or trace, and a single markers panel.
- Several ambient traces can be compared with the emission list and the report.
- The spectrum has a finer frequency resolution.
- Reports show an explicit PASS / FAIL / NOT EVALUATED verdict, the reference level, the attenuator setting and the number of sweeps. Overloaded measurements can no longer pass.
- The spectrogram and CSV traces are kept in the session.

Clickmeter: menus reorganised around the test. The test setup is shown before starting and in the report. When a test is stopped, the reason is given.

General
- Automatic ADC calibration at every start-up.
- Improved band C (30–110 MHz) accuracy.
- The interface clearly shows when the instrument is not connected or is in use from another computer.
- Many stability fixes.

Python API: api_v5 adds modal coefficients and neutral settings, report verdicts and detection of an instrument in use.
(picture for EMSCOPE-RX4 missing) EMSCOPE-RX4 20/11/2026 - Update version 5.0: EMSCOPE-RX4-5.emz - 0MB
Oscilloscope: rebuilt with an acquisition memory of up to 10M points and a full trigger menu (edge, burst, external, HF reject, force). Also new: automatic measurements with statistics, time and amplitude cursors, phase and delay between traces, math traces (A+B, A−B, A×B), Average, Envelope and Peak detect modes, persistence and Autoscale.

EMI measurements
- Better marker handling: peak search, next peak, delta markers against a reference marker or trace, and a single markers panel.
- Several ambient traces can be compared with the emission list and the report.
- The spectrum has a finer frequency resolution.
- Reports show an explicit PASS / FAIL / NOT EVALUATED verdict, the reference level, the attenuator setting and the number of sweeps. Overloaded measurements can no longer pass.
- The spectrogram and CSV traces are kept in the session.

Clickmeter: menus reorganised around the test. The test setup is shown before starting and in the report. When a test is stopped, the reason is given.

General
- Automatic ADC calibration at every start-up.
- Improved band C (30–110 MHz) accuracy.
- The interface clearly shows when the instrument is not connected or is in use from another computer.
- Many stability fixes.

Python API: api_v5 adds modal coefficients and neutral settings, report verdicts and detection of an instrument in use.

What can we do for you? Let’s talk

Contact us

Do you have any questions regarding our solutions and services? Please fill up the form below and we’ll be in touch with you soon.

  • Emzer Technological Solutions, S.L.
  • C/ Llacuna 162. Mod 114. 08018 Barcelona (Spain)
Go to Google Maps




This website uses cookies to enhance your browsing experience. By continuing to visit this site, you consent to our cookies policy. Read Policy